Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Military Medical Sciences ; (12): 759-763,776, 2016.
Article in Chinese | WPRIM | ID: wpr-605615

ABSTRACT

Objective To investigate the clinical value of axillary ultrasound (AUS)in the identification of axillary nodal metastasis (ALNM).Methods Two hundred and eighty-two consecutive patients with stage Tis-T2 breast cancer were prospectively enrolled between December 2013 and September 2015.All the patients underwent AUS performed by two specified senior ultrasound doctors.Sonographic features of their axillary lymph nodes (longitudinal and transverse diameters,cortical and hilar thickness,blood flow form)were collected.These patients were divided into metastatic, suspicious and non-metastatic groups based on the ultrasound features by ultrasound doctors.The diagnostic accuracy of AUS was compared with results of pathology.Univariate and multivariate Logistic regression analyses were used to evaluate the relationship between sonographic features and ALNM.The area under the ROC curve was used to assess the accuracy of the multivariate Logistic regression model.Results The sensitivity,specificity,positive and negative predictive value and accuracy of AUS were respectively 85.6%,87.1%,86.4%,86.3%,and 86.3% in the metastatic and non-metastatic groups.The Kappa value was 0.727(P <0.001).The ALNM burden in the non-metastatic group was significantly lower than in the metastatic group (1.2 vs 6.9,P <0.001).The false-negative results were found only in 16 cases,fourteen of whom had only 1,and two had 2 and 3 ALNM,respectively.Univariate Logistic regression analysis showed that maximum cortical thickness was the most significant predictive factor of ALNM(the area under the ROC curve was 0.872).Multivariate Logistic regression analysis suggested that cortical thickness and the ratio of hilar thickness to cortical thickness were predictive factors of ALNM(P <0.05).The area under the ROC curve of the multivariate Logistic regression model was 0.879 and its sensitivity and specificity were 77.0% and 85.1%,respectively.Conclusion AUS is a valuable tool for detecting ALNM.Patients with false-negative results of AUS have a lower axillary metastatic burden.Maximum cortical thickness is the most significant predictive factor of ALNM.AUS may be a potential alternative method for sentinel lymph node biopsy as axillary lymph node staging in early-stage breast cancer patients.

2.
Military Medical Sciences ; (12): 140-142,146, 2015.
Article in Chinese | WPRIM | ID: wpr-600356

ABSTRACT

Objective To analyze the correlation between the expression of Ki-67 and Her-2 and clinical features in breast invasive ductal carcinoma .Methods Clinical and pathological data of 202 female breast invasive ductal carcinoma patients were collected between January 2012 and September 2014 .The correlation between the expression of Ki-67 and Her-2 and clinical features was analyzed .Results The positive rate of Ki-67 was 73.3%(148/202) and that of Her-2 was 19.3(39/202).The expression of Ki-67 was related to histological grading , ER and PR status(P0.05).The expression of Her-2 was related to ER and PR status (P0.05).Moreover, the low expression Ki-67 and negative expression of Her-2 were positvely corelated with the positive expression of hormone receptor [estrogen receptor(ER),pro-gestin receptor(PR)](P<0.05).Conclusion High expression of Ki-67 suggested that the differential grade of tumor was lower , malignant grade was higher , infiltration was stronger and metastasis was easier .High expression of Ki-67 and positive Her-2 suggests lower sensitivity to endocrine therapy and treatment .Detection of Ki-67 and Her-2 expression in breast inva-sive ductal carcinoma is of guiding significance for understanding the degree of malignancy and for evaluating prognosis .

3.
Military Medical Sciences ; (12): 702-706,716, 2015.
Article in Chinese | WPRIM | ID: wpr-602571

ABSTRACT

Objective To assess the clinical application value of axillary lymph node staging of breast cancer by B ultrasound.Methods From February to December 2014, 200 female breast disease patients in Department of Breast Surgery Affiliated Hospital of Academy of Military Medical Sciences, were enrolled, with median age 50 years old, including 153 cases of breast cancer, 44 cases of fibroadenoma, 2 cases of mastitis and a case of huge fibroma.The state of axillary lymph node was assessed by doctor with more than twenty years experience in B ultrasound diagnosis.According to the characteristics of the ultrasound image of lymph node and experience of the B ultrasound doctor, the patients were divided into axillary lymph node metastasis group, suspicious group and no metastasis group.The axillary lymph nodes were staged by sentinel lymph node biopsy or axillary lymph node dissection.Based on pathological diagnosis and results of the ultrasound, the sensitivity, specificity, positive predictive value, negative predictive value, false negative rate, and metastasis burden of axillary lymph nodes in false negative patients were analyzed.The relationship between the B ultrasound characteristics and axillary lymph node metastasis was also studied by univariate analysis.Results The metastasis rate of above-mentioned 3 groups by B ultrasound was 84.51%, 45.16% and 7.14%, respectively.The sensitivity, specificity, positive predictive value and negative predictive value of screening for axillary lymph node metastasis by B ultrasound were 89.6%, 89.1%, 84.5% and 92.7%, respectively in metastasis group and no metastasis group. According to consistency analysis between pathological diagnosis and B ultrasound, the Kappa value was 0.779.The false negative rate was only 7.1%(7/98 cases) in no metastasis group judged by B ultrasound, and the patients′axillary lymph node metastasis burden was very low, with only one lymph node positive.The univariate analysis showed that patients with longitudinal diameter of lymph nodes≥1 cm had a higher risk for metastasis than 1.5(P<0.001); cortical thickness≥3 mm and lymph node appearing blood flow signal of the central or mixed type were also high metastasis risk factor, the lymph node metastasis rate was 67.5%, 75%and 79%, respectively, P<0.001).Conclusion B Ultrasound is a valuable method for detecting axillary lymph node metastasis in breast cancer.It has lower false negative rate, and the false negative patients just have smaller axillary lymph node metastasis burden.The longitudinal diameter of lymph nodes more than 1 cm, lymph node aspect ratio≤1.5, lymph node of cortical thickness≥3 mm, and blood flow signal of the central or mixed type have higher relationship with axillary lymph node metastasis.B Ultrasound may be a potential alterative method for sentinel axillary lymph node biopsy for axillary lymph node staging in early breast cancer.

4.
Military Medical Sciences ; (12): 373-376, 2015.
Article in Chinese | WPRIM | ID: wpr-463390

ABSTRACT

Objective To verify the reliability of our previously established reverse-transcription loop-mediated isother-mal amplification ( RT-LAMP) method for the detection of sentinel lymph nodes metastasis in breast cancer patients .Meth-ods Sentinel lymph nodes of breast cancer patients were analyzed by RT-LAMP and FDA-approved GeneSearch methods respectively, and the consistency of the two methods was assessed with a kappa concordance test.Results One hundred and thirty-four cases of sentinel lymph node samples were collected from seven hospitals in Beijing .Using the GeneSearch assay as the gold standard, the sensitivity, specificity and consistentcy of RT-LAMP were 96.2%(25/26),96.3%(104/108) and 96.3%(129/134), respectively.Statistical analysis showed that the two methods were consistent (Kappa=0.8857, P<0.001).Conclusion RT-LAMP is highly consistent with GeneSearch ,efficient,simple and inexpensive, promising a good prospect of application to intra-operative detection of sentinel lymph nodes metastasis for breast cancer patients.

5.
Military Medical Sciences ; (12): 541-545, 2015.
Article in Chinese | WPRIM | ID: wpr-461323

ABSTRACT

Objective To analyze the clinical value of ultrasound and ultrasound-guided core needle biopsy ( UNB) in the evaluation of axillary lymph node metastasis for breast cancer.Methods A total of 454 cases of breast cancer treated between June 2008 and August 2014 at our hospital were retrospectively analyzed.UNB was performed on patients with abnormal ultrasonic diagnosis of axillary lymph nodes.Among them, 354 cases underwent neoadjuvant chemotherapy or endocrine therapy while 100 cases underwent surgery after UNB.The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false negative rate of ultrasound and UNB were evaluated.Results Among the 454 patients with abnormal axillary lymph nodes of ultrasound imaging, the metastasis rate with UNB was 70.9%,while the negative rate was 29.1%.Among the 100 cases who underwent surgery after UNB, the metastasis rate was 25% while the ultrasound imaging lymph node longitudinal and transversal ( L/T)≤1.5,the lymph node size>1 cm,and the metastasis rate was 92.3%(12/13).UNB showed that sensitivity was 64.1%, specificity 100%, accuracy 86%, positive predictive value 100%, negative predictive value 81.3%,and false negative rate was 18.7%.The results of UNB seemed consistent with those of postoperative pathological diagnosis, the Kappa value being 0.685.Based on 2 and 3 needles, the above mentioned 6 indices were 50% and 77.8%, 100% and 100%, 77.8% and 92.5%, 100% and 100%, 71.4% and 89.7%,and 28.6%and 10.3%, respectively.The Kappa value of UNB based on 3 needles was higher than on 2 needles (0.822 vs 0.526 ) .Conclusion Ultrasound is a valuable tool for detecting axillary lymph node metastasis in breast cancer.UNB can accurately determine the axillary lymph node metastasis status.UNB based on 3 needles shows a higher accuracy than on 2 needles.

6.
Chinese Journal of Endocrine Surgery ; (6): 309-311,318, 2014.
Article in Chinese | WPRIM | ID: wpr-625068

ABSTRACT

Objective To investigate the clinical features , diagnosis and treatment of ectopic thyroid in order to avoid misdiagnosis and mismanagement .Methods Six cases of ectopic thyroid admitted to Fuzhou Gen-eral Hospital from Jan .2000 to Oct.2011 were retrospectively analyzed and the literatures were reviewed .Re-sults Three cases of ectopic thyroid were located in the anterior cervical area , 2 cases were at the base of the tongue and 1 case in the gall bladder .Two cases of aberrant thyroid were confirmed preoperatively in patients whose gland wasn't discovered by imaging examinations at the normal position of the thyroid gland .A symptomless individual of aberrant thyroid did not need other treatment but follow-up.One case with foreign body sensation in pharynx had a good response to thyroxine therapy .Four cases with accessory thyroid were operated because of misdiagnosis .Three cases were ectopic thyroid tissue and one was nodular goiter confirmed by pathology .None of these patients developed hypothyroidism after surgery .Conclusions Ectopic thyroid gland is a rare disease fre-quently misdiagnosed and mistreated .Goiters in the commonly location of ectopic thyroid gland such as the anteri-or cervical area and the base of the tongue should be paid special attention .Hormonal therapy or surgical inter-vention should be chosen according to clinical features , type of the goiter , thyroid function and whether it is be-nign or malignant .Long term follow-up and thyroid function tests are absolutely necessary .

SELECTION OF CITATIONS
SEARCH DETAIL